Fire protection is not optional, it is a core requirement for any building owner, facility manager or safety professional. Whether you are planning for a commercial office in Noida, a residential complex in Gurgaon or a retail space in Delhi city, you need a fire safety control panel that’s reliable, certified and locally supported.
The GST (Gulf Security Technology) Conventional Fire Alarm Control Panel series models GST102A, GST104A, GST108A and GST116A are globally trusted for small- to medium-size fire-alarm installations.

This guide will help you understand their specifications, features, applications, how to pick the right model and how to buy one in the Delhi NCR region with confidence.
What the GST Conventional Fire Alarm Control Panel Series Are
The GST conventional panel series (GST102A/104A/108A/116A) are conventional fire alarm control equipment designed for fire-detection systems in buildings. They are built to monitor zones wired with conventional detectors (smoke, heat) and manual call points, trigger sounders, alarms and fault notifications. They comply with international standards and provide a robust foundation for fire-alarm installation.
Features & Technical Specifications
Here’s a summary of the major features and specifications of the GST conventional panel series:
Features
- Zone capacities: 2, 4, 8 or 16 detection zones (for GST102A/104A/108A/116A respectively).
- Each zone supports multiple conventional detectors and manual call points (up to 32 devices per zone).
- Includes multiple sounder outputs, alarm output, fault output.
- Programmable features: sounder delay modes, output delay, disable/test functions.
- Three access levels (via key switch/internal switch) for safe operation and programming.
- Space for sealed lead-acid standby batteries, ensuring system operation during power failure.
- Designed for indoor installation with ambient range 0 °C-40 °C and relative humidity up to 95% non-condensing.
Technical Specifications
- Power input: 220/230 VAC ±10% / −15%, 50/60 Hz.
- Maximum detectors per zone: Up to 32 devices (varies by model).
- Loop voltage for detection zones: approx. 15-28 VDC.
- Dimensions (typical): 430mm (L) × 98mm (D) × 320mm (H) for the panel cabinets.
- Standards compliance: EN 54-2 and EN 54-4 (for control & indicating equipment).
- Optional relay boards/expansion for additional fault/alarm outputs (especially in larger models).
Model Comparison – Which One Suits Your Building in Delhi NCR?
Here’s a quick comparison table for the series:
| Model | Zone Capacity | Typical Use Case |
|---|---|---|
| GST102A | 2 zones | Small shops, single-floor offices, small clinics |
| GST104A | 4 zones | Medium-sized commercial units, small schools, multi-room offices |
| GST108A | 8 zones | Multi-floor offices, small apartment buildings, retail complexes |
| GST116A | 16 zones | Large buildings, institutional campuses, larger residential complexes |
By selecting a panel with a little extra zone capacity, you leave room for future expansion, e.g., adding new wings/floors.
Example: In Delhi NCR, if your building has 5 distinct floors or zones, a 4-zone model may suffice but opting for the 8-zone model gives flexibility.
Why Choose GST Conventional Panels in Delhi NCR?
Here are reasons why the GST series stands out for installations around Delhi, Noida, Gurgaon, Faridabad & Ghaziabad:
- Globally recognised standards: These panels comply with EN 54, a benchmark for fire detection/alert in many countries.
- Proven reliability: The GST brand has long presence in India and globally, with trained installers, availability of spare parts and service network.
- Compatibility & ease of installation: The panels work with GST’s conventional detectors, manual call points and sounders, making system design simpler.
- Suitable for small to medium installations: Ideal for many buildings in Delhi NCR which don’t require full addressable systems but still demand reliable fire protection.
- Local support potential: In the Delhi-NCR region, authorised GST distributors offer product supply, commissioning, maintenance and training.
Buying & Installation Considerations in Delhi NCR
When you decide to buy a GST Conventional Fire Alarm Control Panel in Delhi NCR, keep the following checklist in mind:
1. Verify Dealer / Distributor
- Ensure the supplier is an authorised GST distributor or partner (e.g, Innxeon). Genuine panels matter for warranty, compliance and after-sales support.
- Ask for product datasheet, manual, certificate of compliance (EN 54) and warranty documentation.
2. Confirm Model & Specification
- Choose the correct model (2, 4, 8 or 16 zones) based on your building’s size and fire-safety design.
- Confirm compatibility with detectors, call points and sounders you plan to install.
- Ask about expansion options (relay boards, repeater interfaces) if you may grow later.
3. Installation & Wiring
- Ensure the installation follows wiring diagrams from the manual, each zone supports up to 32 devices, recommended cable lengths and types.
- Use FRLS (Fire-Retardant Low Smoke) cables, shielding and proper termination.
- Install in a well-ventilated indoor location (0 °C–40 °C range suits Delhi NCR climate).
- Provide battery backup and check that battery type (sealed lead-acid 2×12 V) is compatible as per manual.
4. Commissioning & Testing
- After wiring and connection, commission the panel: set sounder modes, delays, disable/test zones if needed.
- Perform a full system test: zone activation, sounder alarm, fault simulation, battery fail-over.
- Provide training to local facility staff on resetting, silence, disable features, fault acknowledgement.
5. Maintenance & Lifecycle
- Inspect monthly: check panel LEDs, any fault indicators, battery status.
- Annually: perform full servicing, cleaning, battery replacement (typically every 2-3 years or as per local conditions).
- Maintain documentation of tests & servicing for compliance (especially for offices, residential buildings in Delhi NCR under fire-safety norms).
Applications of GST Conventional Panels in Delhi NCR
These panels are suited for a variety of buildings around Delhi NCR:
- Small offices and shops in Delhi city, Connaught Place, Laxmi Nagar.
- Multi-room clinics, educational institutions in Noida or Ghaziabad.
- Apartment buildings, gated communities in Gurgaon or Faridabad.
- Retail malls or showrooms where full addressable systems may be overkill.
- Warehouses or light-industrial facilities where zoned conventional detection suffices.
Because the system is modular and well supported, you can scale from small to medium installations and maintain compliance with local fire-safety norms.
Pricing Insights for Delhi NCR
While exact pricing may vary depending on supplier, accessories and installation charges, typical ballpark figures (2025 estimate) for the GST conventional panel series in India are:
- 2-zone model (GST102A): modest cost, suited for very small installations
- 4-zone model (GST104A): higher than 2-zone but still cost-effective
- 8-zone model (GST108A): more significant investment, good value for larger buildings
- 16-zone model (GST116A): highest cost in the series, for large zone count installations
Note: Additional costs for detectors, call points, sounders, cables, labour and commissioning should be factored in. Always obtain a detailed quotation from an authorised dealer in Delhi NCR.
If you’re looking to buy a GST Conventional Fire Alarm Control Panel in Delhi NCR, the GST102A/104A/108A/116A series offers a dependable, standards-compliant and scalable solution. With the right model selected, proper installation and ongoing maintenance, you’ll deliver state-of-the-art fire-alarm protection for your building, in alignment with regulatory expectations and good safety practice.
Read More: Find Authorized GST Fire Alarm Distributors in India: Innxeon
Read More: GST-200 Addressable Fire Alarm Panel: Specifications, Price & Datasheet









