Which GST Fire Alarm Panel is Right for Your Project? (IFP8, 200N Series, 100 Series or IFP4E)

When it comes to protecting people, property and assets, choosing the right fire alarm panel is the backbone of any effective fire safety system. GST (Gulf Security Technology), a globally trusted name in intelligent fire detection, offers a range of addressable fire alarm control panels tailored to projects of every size.

In this detailed guide, we’ll compare four leading GST fire alarm panels, IFP8, 200N Series, 100 Series and IFP4E, to help you decide which one fits your project’s scale, functionality and budget.

Which GST Fire Alarm Panel is Right for Your Project_ (IFP8, 200N Series, 100 Series or IFP4E)
GST fire alarm panels — reliable protection for every building scale.

Why Choosing the Right Fire Alarm Panel Matters

A fire alarm panel is the central intelligence unit of your fire detection system. It monitors devices, processes signals, triggers alarms and manages communication across loops and zones. Selecting the right panel ensures:

  • Reliable performance and fewer false alarms.
  • Smooth system scalability for future expansion.
  • Compliance with EN54, NFPA and local fire codes.
  • Simplified maintenance and long-term cost efficiency.

Choosing the wrong panel can lead to capacity limitations, networking issues or non-compliance with local fire safety regulations.

Factors to Consider Before Selecting a Panel

Before exploring individual models, assess these factors for your site:

ParameterWhat It MeansWhy It Matters
Project SizeNumber of loops, devices and zonesDetermines panel capacity required
ScalabilityAbility to expand in futurePrevents full system replacement
NetworkingNeed for linking multiple panelsRequired for campuses and large buildings
FeaturesTouchscreen, logic programming, history logsImpacts ease of use and control
ComplianceEN54, BIS, LPCB certificationsEnsures legal and insurance approval
BudgetPurchase + maintenance costAvoids overpaying for unused features

Overview of the Four GST Fire Alarm Panels

Let’s explore each GST fire alarm panel in detail, from basic single-loop models to advanced, multi-loop, network-ready control units.

GST 100 Series: Compact and Cost-Effective

Best for: Small offices, shops, clinics, small industrial units

Features:

  • Single Class A loop supporting up to 128 addressable devices.
  • 8 detection zones with individual fire/fault indicators.
  • Built-in auto-learn configuration and user-friendly interface.
  • Compliant with EN54-2 and EN54-4 standards.

Pros:

  • Affordable and easy to install.
  • Perfect for standalone systems.
  • Minimal maintenance and power requirements.

Cons:

  • Not scalable for multi-floor or multi-building systems.
  • Limited networking capabilities.

Verdict:
The GST 100 Series is ideal for small premises that need basic fire detection without networking or heavy programming. It’s a reliable entry-level choice.

GST 200N Series: Balanced and Scalable

Best for: Small to medium buildings (schools, offices, showrooms)

Features:

  • Available in 1-loop and 2-loop versions.
  • Each loop supports up to 235 devices (total ~470).
  • 30 zones with dedicated alarm/fault LEDs.
  • Supports basic networking through optional cards.
  • EN54-compliant with LCD display and event log memory.

Pros:

  • Flexible for small-to-medium projects.
  • Simple interface with decent expansion capability.
  • Reliable and field-proven design.

Cons:

  • Loop capacity limited compared to IFP4E or IFP8.
  • Advanced logic programming not supported.

Verdict:
Choose the GST 200N if you want a balance of affordability and scalability. Perfect for 1–2 floor office buildings, schools and mid-sized commercial setups.

GST IFP4E: Smart Panel for Complex Projects

Best for: Mid to large projects, hotels, hospitals and data centres

Features:

  • Supports 1 to 6 Class A loops, each handling up to 242 devices.
  • Total capacity: 1,452 devices.
  • 7-inch color touchscreen with graphical display (800×480 resolution).
  • Advanced cause-and-effect logic (AND/OR/NAND/NOR).
  • Stores up to 100,000 event records.
  • Multi-language interface and automatic device learning.
  • Network up to 250 nodes via CAN, Fiber, or TCP/IP.
  • Fully compliant with EN54-2/4.

Pros:

  • Intelligent interface and easy configuration.
  • Ideal for integration with BMS and other ELV systems.
  • Future-ready with strong networking and event history.

Cons:

  • Higher cost and requires trained technicians.
  • More complex setup compared to 100 or 200N series.

Verdict:
The IFP4E is a feature-rich panel that combines scalability with intelligence. It’s the best fit for projects needing smart automation and future-proof flexibility.

GST IFP8: The Powerhouse for Large-Scale Installations

Best for: Airports, malls, campuses, large industrial plants

Features:

  • Handles up to 8 loops with 242 devices per loop.
  • Supports 999 zones (140 with dedicated LEDs).
  • Network up to 100 panels (Class A) or 240 panels (Class B).
  • Large LCD (15×40 characters) and 17 LED indicators.
  • Built-in redundancy and self-diagnostics.
  • EN54-2/4 certified.

Pros:

  • Massive scalability and multi-panel networking.
  • Reliable in critical environments with multiple fire zones.
  • Ideal for multi-building and high-rise networks.

Cons:

  • Complex commissioning process.
  • Higher initial investment.

Verdict:
Choose the IFP8 when your project demands maximum capacity, high reliability and full networking control. It’s GST’s most powerful panel.

Comparison Table: GST Fire Alarm Panels at a Glance

ModelLoopsMax DevicesNetworkingBest ForApprox. Cost
GST 1001128NoSmall sites₹36,500
GST 200N1–2470LimitedMedium sites₹1,72,000
GST IFP4E1–61,452Up to 250 nodesLarge projects₹2,00,000+
GST IFP8Up to 81,900+Up to 240 panelsCampuses & high-rises₹2,13,000+

How to Choose the Right GST Fire Alarm Panel

Step 1: Identify Your Project Size

  • Small (≤100 devices): GST 100
  • Medium (100–400 devices): GST 200N
  • Large (400–1,000 devices): IFP4E
  • Extra-Large (>1,000 devices): IFP8

Step 2: Check Networking Needs

  • Standalone system? Go for GST 100 or 200N.
  • Multiple buildings? Choose IFP4E or IFP8.

Step 3: Evaluate Feature Requirements

  • Basic control: 100 / 200N series.
  • Touchscreen, logic programming: IFP4E or IFP8.
  • Integration with BMS or Smart systems: IFP4E preferred.

Step 4: Assess Future Scalability

  • Projects with future expansion potential should avoid small fixed-loop panels.
  • IFP4E or IFP8 offer loop expansion and network growth options.

Step 5: Set a Realistic Budget

  • Always balance between initial cost and system longevity.
  • Spending slightly more now often saves major upgrade costs later.

Real-World Examples

Project TypeTypical Device CountRecommended Panel
Small retail store30–60GST 100
2-floor office200–400GST 200N
200-bed hospital600–1,000GST IFP4E
Shopping mall / campus1,500+GST IFP8

Expert Tips for Smooth Project Execution

1. Plan Early: Calculate loop length, device load and spare capacity before design finalization.
2. Ensure Cable Quality: Use fire-rated, twisted pair loop cables (as per EN54).
3. Check Panel Compliance: Confirm EN54 or BIS approval in documentation.
4. Use Loop Isolators: To prevent complete loop failure during a short circuit.
5. Train Operators: Ensure your staff understands alarm acknowledgment, reset and fault handling.
6. Maintain Regular Testing: Periodic loop testing ensures ongoing reliability.
7. Document Everything: Maintain loop diagrams, addresses and maintenance logs.

Summary: Which GST Panel Should You Choose?

PanelIdeal ForWhy Choose It
GST 100Small single-floor sitesSimple, economical, easy setup
GST 200NMedium buildingsBalanced cost and capacity
GST IFP4ELarge and smart systemsAdvanced touchscreen and logic functions
GST IFP8Very large or multi-building networksMaximum capacity and networking strength

Every fire alarm project is unique, the right GST panel depends on your site layout, expansion plans and integration needs.

  • Choose GST 100 or 200N for standalone buildings with limited devices.
  • Opt for IFP4E or IFP8 for advanced control, multi-panel networking, and large-scale safety management.

Partner with a certified GST distributor or system integrator to ensure proper design, installation and commissioning. The right panel today can make your fire safety system reliable for decades.

Read Also: Best GST Addressable Fire Alarm System for Manufacturing Plants

Read Also: Buy GST Smoke Detectors & Heat Detectors: Full Range for Commercial Buildings

Written By: